Setup 161
Manual Control
This user setting button gives you access to manual control settings.
Manual Time
In this section you may change the default times for manual changes to occur in live. Times can be
set for each parameter category (Intensity Up, Intensity Down, Focus, Color, and Beam). You may
use the [Thru] key to enter a value for all categories.
{Int Up} [Thru] [9][Enter]
The default for each of these is 0 seconds.
Manual Control
This section allows you to specify the values for certain buttons or settings used in manual control.
To change any value, touch the appropriate button in the CIA and use the keypad to enter a new
value. Fields are:
Level - This sets the value for the [Level] key. Any value between 0-100 may be entered. The
default is 100.
Plus% - This sets the level for the [+%] key, which will increase the selected channel by the set
percentage. You can assign +% to values that have up to five digits. The default is 10%.
Minus% - This sets the level for the [-%] key, which will decrease the selected channel by the
set percentage. You can assign -% to values that have up to five digits. The default is 10%.
Highlight Preset - This field is used to specify the preset that will be used for any highlight com-
mands.
Lowlight Preset - This field is used to specify the preset that will be used for any lowlight com-
mands.
Highlight Rem Dim - This enables a remainder dim when in highlight mode, thereby tem-
porarily dimming any channel not participating in the High/Low. An intensity level or a preset
can be assigned in this field. Channels not in highlight or lowlight that are not included in the
RemDim IP or preset are not affected.
Live RemDim Level - This allows you to set the level for all remainder dim commands in live.
The default is 0. An intensity level or a preset can be assigned in this field.
Default Times
In this section you may change the default times for sneak commands and the respective feature
response times based upon parameter category. The default for these is 5 seconds, except for back
time, which uses a default of 1 second. You can assign separate timing values to the Release and Off
functions.
You can assign [Cue] as a timing value for the {Go to Cue Time} and {Back Time} The syntax, {Go to
Cue Time} [Cue] [Enter] or {BackTime} [Cue] [Enter] will assign cue as the timing value.
When [Go To Cue] [n] [Enter] or [Back] is used, the fade will happen in the time set in the destination
cue.
You can assign a separate time value for [Timing Disable]. When a fader has been set to timing dis-
able mode, cues will use the time set in Setup. The default time is 0.
User Displays
This user setting button gives you access to the following display settings:

Table of Contents

Other manuals for ETC Element 2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ETC Element 2 and is the answer not in the manual?

ETC Element 2 Specifications

General IconGeneral
DMX Outputs2
TouchscreenYes
NetworkingEthernet
TypeLighting Control Console
Master Faders2
Encoders4
Ethernet Ports2
USB Ports4
Video OutputDisplayPort
Power Input100-240VAC, 50/60Hz
Power SupplyInternal
Control Channels6144