282 Eos Family Operations Manual
Master type (Proportional, Manual Master, or Intensity Master)
Intensity HTP or LTP setting (default is LTP)
Assert
Priority
Background
Background Priority
Phantom
Back from 1st
Go from Last
Stomp
Exclude
Channel Filters
ParameterFilters
Faders can be mapped to a cue list in the fader configuration display or by using [Load], see Selected
Cue for more information. If a fader has been configured for default mapping (see Fader Con-
figuration (on page87) for more information), the fader will receive its configuration from the Cue
List Index. Changes made to a cue list in the cue list index will be shared with any default mapping
faders loaded with that cue list. If changes are made to a fader set to default mapping in the fader
configuration display, those changes will also happen in the Cue List Index. If set to Local, any
changes made in the fader configuration display will impact only that instance of the content.
Master
A fader can be assigned as a Master. When it is a master, its behavior as a Proportional Master,
Manual Master or Intensity Master (I-Master) is drawn from this setting.
Proportional faders, when the slider is set to zero prior to the execution of a cue, will withhold
playback of intensity data until the fader is raised. Intensity data will then be played back pro-
portionally according to the level of the fader. Once the fader reaches full, the cue is con-
sidered complete and the cue is released from the manual fader. If the fader is at any value
other than zero when the cue is executed, intensity values will play back normally. If the slider
is returned toward zero, intensity in the cue will fade to the previous level.
Intensity Masters will master the intensity level for cues during playback. Therefore, intensity
masters set below 100% will proportionally limit playback of intensity data relative to the level
that the fader is set. All non-intensity parameters are unaffected by the fader. Once the fader
has reached full, control of intensity is retained. If the fader is moved toward zero, intensity
will proportionally fade toward zero (not the previous state as per proportional faders).
In Manual Master mode, cues are triggered manually by faders without using the [Go] button.
With a cue list on a fader set to manual master, a cue will fire in manual time when the fader is
moved from 0% or from Full. Timing is scaled. So, if color has a 5 count delay, and the dur-
ation of the cue is 10, the color transition will not begin until the faders manually reach 50%.
Follow and hang times will be ignored when firing a cue with a manual master fader.
HTP
Intensity playback behavior can be set to HTP (highest takes precedence) or LTP (latest takes pre-
cedence). For cues, it defaults to LTP.