Show Control 519
Go
When accompanying a MIDI “Go” command, data for the following fields will result in the following
actions:
Cue DataField List Data Field Action
Cue List Runs the specified cue in the specified cue list
Cue - Runs the specified cue in cue list 1
- List Runs the next cue in the specified list
- - Runs the next cue in cue list 1
Stop
When accompanying a MIDI “Stop” command, data for the following fields will result in the fol-
lowing actions:
Cue DataField List Data Field Action
Cue List Stops the specified cue & list (if running)
Cue - Stops the running cue in cue list 1
- List Stops the current cue from the specified list
- - Stops the running cue on the master fader of the console that received the command
If a cue is not currently running (or already stopped), the Stop command will trigger Back, fading
back to the previous cue.
Resume
When accompanying a MIDI “Resume” command, data for the following fields will result in the fol-
lowing actions. If there are no stopped cues, this action is ignored.
Cue DataField List Data Field Action
Cue List Resumes the specified cue & list (if stopped)
Cue - Resumes the specified cue in the default cue list
- List Resumes the current cue in the specified list
- - Resumes all stopped cues
Set
The “Set” command allows MSC to control specific faders using both a numeric control value
(which specifies the fader number) and a data field (which controls the level: 0-100). Control values
are as follows:
Control Value Data Field Indication
1-127 0-100 Submaster 1-127
128 0-100 Primary playback in
129 0-100 Primary playback out
510 0-100 Grandmaster
All other control values are ignored.
Note: See Hexadecimal and MIDIShow Control Formatting (on thenext page) for inform-
ation on formatting MIDI messages.