CNC 8070
12
·225·
(REF: 1709)
ADDITIONAL PREPARATORY
FUNCTIONS
12.1 Dwell (G04 / #TIME).
The F04 function and the #TIME instruction may be used to interrupt the execution of the
program for the specified period of time. Both commands are equivalent and either one may
be used.
Programming (1). G04.
Program function G04 and then the dwell time.
Programming format.
The programming format is the following; the arguments appear between curly brackets and
the optional ones between angle brackets. The K command may be left out when the dwell
is programmed with a constant.
G04 K{time}
G04 {time}
Programming (2). #TIME.
The dwell must be programmed with programming this instruction.
Programming format.
The programming format is the following; the arguments appear between curly brackets and
the optional ones between angle brackets. If the time is programmed with a constant or a
parameter, the brackets [] may be left out .
#TIME [{time}]
#TIME {time}
K{time} Dwell.
Units: Seconds.
{time} Dwell (programmed with a constant).
Units: Seconds.
G04 K0.5
(0.5 second dwel)
G04 8.5
(8.5 second dwel)
P1=3
G04 KP1
(3 second dwel)
P1=3
G04 K[P1+7]
(10 second dwel)