82
To Delete Data for an Event Page:
(1) Press the ±/EVENT button at the top right-hand side of the menu display. The [EVENT
MEMORY] menu is displayed.
(2) Turn F1 to select an event page to be deleted.
(3) Turn F3 to set PAGECLR to CRNT (current), then press F3. The data saved in the event
page will then be cleared.
EVENT : PAGE :DIRECT :PAGECLR:LAST : 1/1
MEMORY : =1 : =OFF : =CRNT : :
To Delete All Event Data :
(1) Press the ±/EVENT button at the top right-hand side of the menu display. The [EVENT
MEMORY] appears.
(2) Set PAGECLR to ALL, and press F3. All event data is cleared.
EVENT : PAGE :DIRECT :PAGECLR:LAST : 1/1
MEMORY : =0 : =OFF : =ALL : :
16-5. Loading Event at Start-up
The settings made for the BKGD, KEYER, DSK and PinP buses on the control panel are cleared
when powering off the switcher. You can, however, recall the desired panel setup whenever the
switcher starts by setting in the [SETUP-SYSTEM-INIT] menu as shown in the procedure below.
(1) Press the MENU button at the right of the menu display.
(2) Press the 7/SETUP button to display the SETUP menu's top page.
(3) Turn F1 to select SYSTEM and then press F1.
SETUP :>SYSTEM >INPUT >OUTPUT >PANEL
MENU :>EXT I/F >STATUS
(4) The [SETUP - SYSTEM] menu as shown below appears. Turn F1 to select INIT and then
press F1 to display the [SETUP-SYSTEM-INIT] menu.
SETUP :>FORMAT >REF I/O >ARCNET >ETHERNET
SYSTEM :>TIME >INIT >REBOOT
SYSTEM : INIT : LOAD : : 1/1
INIT : >CURRENT : =LAST : :
(5) Turn F3 to select the desired panel setup in the table below
LOAD setting Description
OFF The switcher starts with the factory default settings.
LAST
The switcher starts with the last loaded event.
Note that to enable the Last Load function, an event must be
loaded after setting to LAST.
0-99 The switcher starts with loading an event (0-99).