â–¶
Click Start Fan T
est.
For more information on iRMC settings, see the iRMC user guides.
Executing the fan test via ServerView Operations Manager
â–¶
Open the ServerV
iew Operations Manager and log in.
â–¶
Under Administration select Server Configuration.
â–¶
In the hierarchy tree of the Server list tab, select the server to be
configured.
â–¶
In the right-hand side of the window, specify the details on the selected
server and confirm your entries by clicking GO.... In the left-hand section of
the window, the Configuration tab is being activated.
â–¶
In the navigation area of the Configuration tab, select Other Settings.
â–¶
Under Daily Fan Test, set the daily fan test time to a few minutes from the
current time. (Ensure to note down your previous setting.)
â–¶
Click Save Page.
The fan test will be started at the specified time.
â–¶
After the fan test is complete, restore the time setting to its initial value and
click Save Page.
In case of maintenance done by Fujitsu engineers in Japan:
Executing the fan test via Chassis ID Prom Tool
Please follow the instructions provided separately.
Basic software procedures
RX4770 M5 Upgrade and Maintenance Manual 119