6 Power supply unit (PSU)
6.1
Safety notes
CAUTION
â–¶
Do not disassemble the PSU. Doing so may cause electric shock.
â–¶
Areas around the PSU may remain extremely hot after shutdown.
After shutting down the server
, wait for hot components to cool
down before removing the PSU.
â–¶
When installing a PSU, ensure that the connector of the PSU is not
damaged or bent.
â–¶
The PSU is heavy, so handle it carefully. If you drop it by mistake,
injuries may result.
â–¶
For more information, see "Important information" on page 29.
6.2 Basic information
The server is equipped with two hot-plug PSUs that automatically adjust to any
mains voltage in the range of 100
V - 240 V.
If one hot-plug PSU fails, the second hot-plug PSU in the redundant
configuration ensures that the operation can continue uninterrupted and the
defective PSU can be replaced during operation (hot-plug).
CAUTION
The server supports a mains voltage in the range of 100 V to 240 V
(1600 W PSUs).
â–¶
You may only operate the server if its rated voltage range
corresponds to the local mains voltage.
PSU configurations
Configuration PSU1 PSU2
1 1600 W 1600 W
RX4770 M5 Upgrade and Maintenance Manual 121