Ensure that all pre-fail/fail status issues have been resolved in ServerV
iew
Operations Manager.
Using Infrastructure Manager
The status of server (node) which failed memory module is installed becomes
error.
When replacing the memory module, the status will be updated after getting
information manually or automatically updated daily.
Proceed as follows to get node information with Infrastructure Manager:
▶
Start up the GUI of the Infrastructure Manager and login.
▶
Display the node list from menu (manage > node).
▶
Select the target node and display the detail screen.
▶
Execute getting node information from action menu.
5.3.8 Enabling the boot watchdog
If the boot watchdog has been disabled for firmware upgrade purposes (see
"Disabling the boot watchdog" on page 86), it has to be re-enabled to complete
the maintenance task.
Timer settings can be configured in the BIOS or using the ServerView iRMC
web interface.
Enabling the boot watchdog in the BIOS
▶
Enter the BIOS.
▶
Select the Server Mgmt menu.
▶
Under Boot Watchdog set the Action setting to Reset.
▶
Save your changes and exit the BIOS.
For more information on how to access the BIOS and modify settings,
see the corresponding BIOS Setup Utility reference manual.
Basic software procedures
RX4770 M5 Upgrade and Maintenance Manual 101