Enter the commands below
, followed by [ENTER]:
1. /etc/init.d/srvmagt stop
/etc/init.d/srvmagt_scs stop
/etc/init.d/eecd stop
/etc/init.d/eecd_mods_src stop
2. cd /etc/srvmagt
3. rm -f cehist.bin
4. /etc/init.d/eecd_mods_src start
/etc/init.d/eecd start
/etc/init.d/srvmagt start
/etc/init.d/srvmagt_scs start
â–¶
Ensure that all pre-fail/fail status issues have been resolved in ServerView
Operations Manager.
Using Infrastructure Manager
The status of server (node) which failed CPU is installed becomes error.
When replacing the CPU, the status will be updated after getting information
manually or automatically updated daily.
Proceed as follows to get node information with Infrastructure Manager:
â–¶
Start up the GUI of the Infrastructure Manager and login.
â–¶
Display the node list from menu (manage > node).
â–¶
Select the target node and display the detail screen.
â–¶
Execute getting node information from action menu.
5.3.7.2 Resetting the error status after replacing memory modules
In case of a memory error, an error counter may be set for the defective
memory module.
Basic software procedures
RX4770 M5 Upgrade and Maintenance Manual 99

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY RX4770 M5 and is the answer not in the manual?

Fujitsu PRIMERGY RX4770 M5 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY RX4770 M5
CategoryServer
LanguageEnglish

Related product manuals