Both CPUs must be of the same type
For system relevant information, see the hardware configurator of your
server available online at the following address:
https://ts.fujitsu.com/products/standard_servers/index.htm
For Japan:
https://www.fujitsu.com/jp/products/computing/servers/primergy/
11.3 Upgrading to 4 CPU configuration
Upgrade and Repair Unit
(URU)
Hardware: 15 minutes
Software: 5 minutes
Tools: Phillips PH2 / (+) No. 2 screw driver
CAUTION
CPUs are extremely sensitive to electrostatic discharge and therefore
must always be handled with care.
â–¶
After a CPU has been removed from its protective sleeve or from its
socket, place it upside down on a nonconducting, antistatic surface.
â–¶
Never push a CPU over a surface.
CAUTION
â–¶
Only CPUs of the same type may be used on the system board.
That means the number of the internal CPU cores as well as the
primary clock and the QPI frequency have to be the same.
â–¶
For dual operation, use a suitable multiprocessor OS.
Preliminary steps
â–¶
"Suspending BitLocker functionality" on page
85.
â–¶
"Shutting down the server" on page 45.
â–¶
"Disconnecting the power cord" on page 46.
Processor (CPU)
272 Upgrade and Maintenance Manual RX4770 M5