Status Description
blue on The server has been highlighted using ServerView
Operations Manager
, iRMC web interface or the ID
button on the front panel for easy identification.
flashing blue The server has been highlighted for easy
identification using the iRMC (AVR) with disabled
local VGA output.
CSS indicator (3)
Status Description
off No critical event detected (CSS component).
orange on Prefailure event detected (CSS component).
For HDDs, see also "HDD prefailure detection" on
page
426.
flashing orange CSS component failure detected.
Global Error indicator (4)
See also "iRMC-related status signals" on page
426.
Status Description
off No critical event detected (non-CSS component).
orange on Prefailure event detected (non-CSS component).
flashing orange Non-CSS component failure detected.
Possible causes:
–
System is out of the specified temperature range
– Defective sensor
– CPU error
– Error detected by server management software
Appendix A
RX4770 M5 Upgrade and Maintenance Manual 425