Beep
Description Action
1 Memory not installed
â–¶
Check if the memory module is
installed.
â–¶
Check if the memory module is
installed correctly.
2 Recovery started Recovery procedure is initialized by
jumper settings on the system board and
announced with two beep.
This is only an information.
4 Recovery failed
â–¶
Restart the recovery procedure again.
â–¶
If the same beep code sounds again,
replace the system board.
DXE Beep Codes
Driver Execution Environment (DXE) - main hardware Initialization (POST)
# of
Beep
Description Action
1 Invalid password
â–¶
Check for the correct password and try
again. Make sure that the caps lock key
is deactivated.
5 No Console Input
devices
1
or Output
devices
2
are found
Booting will continue.
1
Serial console redirection is considered
a console output device if enabled.
2
Serial console redirection is considered
a console input device if enabled.
This beep code is only an information.
6 Flash update is failed A processing bar and an error message is
displayed on the screen.
This beep code is only an information.
Appendix A
RX4770 M5 Upgrade and Maintenance Manual 431

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY RX4770 M5 and is the answer not in the manual?

Fujitsu PRIMERGY RX4770 M5 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY RX4770 M5
CategoryServer
LanguageEnglish

Related product manuals