Field Description
Possible values are 1 to 255.
The default value is 7.
Long Retry Limit Enter the maximum number of attempts to send a data packet
of length less than or equal to the value defined in RTS
Threshold. After this many failed attempts, the packet is dis-
carded.
Possible values are 1 to 255.
The default value is 4.
Fragmentation
Threshold
Enter the maximum size as of which the data packets are to be
fragmented (i.e. split into smaller units). A low value is recom-
mended for this field in areas with poor reception and in the
event of radio interference.
Possible values are 256 to 2346.
The default value is 2346 bytes.
ED Threshold Not for bintec W1002n
Here, you can define the Energy Detection threshold for CCA
(Clear Channel Assessment).
Possible values are -2147483648 to 2147483647.
The default value is 0.
CW Min. Not for bintec W1002n
Here, you can define the maximum size of the contention win-
dow.
Possible values are 1 to 65535.
The default value is 15.
CW Max. Not for bintec W1002n
Here, you can define the minimum size of the contention win-
dow.
Possible values are 1 to 65535.
Funkwerk Enterprise Communications GmbH
11 Wireless LAN
bintec W1002/W1002n/W2002/WIx040/WIx065 149

Table of Contents

Other manuals for Funkwerk W1002

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Funkwerk W1002 and is the answer not in the manual?

Funkwerk W1002 Specifications

General IconGeneral
BrandFunkwerk
ModelW1002
CategoryWireless Access Point
LanguageEnglish

Related product manuals