Field Description
Possible values:
• All (default value): All firewall activities are displayed.
• Deny : Only reject and deny events are shown, see "Action".
• Accept : Only accept events are shown.
• None: Syslog messages are not generated.
Fields in the OptionsSession Timer menu
Field Description
UDP Inactivity Enter the inactivity time after which a UDP session is to be re-
garded as expired (in seconds).
Possible values are 30 to 86400.
The default value is 180.
TCP Inactivity Enter the inactivity time after which a TCP session is to be re-
garded as expired (in seconds).
Possible values are 30 to 86400.
The default value is 3600.
PPTP Inactivity Enter the inactivity time after which a PPTP session is to be re-
garded as expired (in seconds).
Possible values are 30 to 86400.
The default value is 86400.
Other Inactivity Enter the inactivity time after which a session of another type is
to be regarded as expired (in seconds).
Possible values are 30 to 86400.
The default value is 30.
15.2 Interfaces
Funkwerk Enterprise Communications GmbH
15 Firewall
bintec W1002/W1002n/W2002/WIx040/WIx065 283

Table of Contents

Other manuals for Funkwerk W1002

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Funkwerk W1002 and is the answer not in the manual?

Funkwerk W1002 Specifications

General IconGeneral
BrandFunkwerk
ModelW1002
CategoryWireless Access Point
LanguageEnglish

Related product manuals