Field Description
Local IP Address
Enter the IP address to be used as the source address for this
GRE connection.
Route Entries
Define other routing entries for this connection partner.
Add a new entry with Add.
• Remote IP Address: IP address of the destination host or
network.
• Netmask: Netmask of Remote IP Address. If no entry is
made, your device uses a default netmask.
• Metric: The lower the value, the higher the priority of the
route (possible values 0... 15). The default value is 1.
MTU
Enter the maximum packet size (Maximum Transfer Unit, MTU)
in bytes that is allowed for the GRE connection between the
partners.
Possible values are 1 to 8192.
The default value is 1500.
Use Key
Enable the key input for the GRE connection, which makes it
possible to distinguish between several parallel GRE connec-
tions between two GRE partners (see RFC 1701).
The key is activated with Enable.
The function is disabled by default.
Key Value
Only if Use Key is enabled.
Enter the GRE connection key.
Possible values are 0 to 2147483647.
The default value is 0.
14.5 Certificates
Funkwerk Enterprise Communications GmbH
14 VPN
bintec W1002/W1002n/W2002/WIx040/WIx065 263

Table of Contents

Other manuals for Funkwerk W1002

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Funkwerk W1002 and is the answer not in the manual?

Funkwerk W1002 Specifications

General IconGeneral
BrandFunkwerk
ModelW1002
CategoryWireless Access Point
LanguageEnglish

Related product manuals