Fig. 143: Local Services->Surveillance->Ping Generator->New
The Local Services->Surveillance->Ping Generator->New menu consists of the follow-
ing fields:
Fields in the Ping GeneratorBasic Parameters menu
Field Description
Destination IP Address Enter the IP address to which the ping is automatically sent.
Source IP Address Enter the source IP address of the outgoing ICMP echo request
packets.
Possible values:
• Automatic: The IP address is determined automatically.
• Specific (default value): Enter the IP address in the adja-
cent input field e.g. to test a particular extended route.
Interval Enter the interval is seconds during which the ping is to be sent
to the target IP address specified in Target IP Address.
Possible values are 1 to 65536.
The default value is 10.
16.6 Funkwerk Discovery
Funkwerk Enterprise Communications GmbH
16 Local services