Field Description
The default value is 0.
Metric Offset on Inter-
face dormant
Select the value to be added to the route metric if the status of
the interface is "dormant". During export, the value is added to
the exported metric if the interface status is "dormant".
Possible values are -16 to 16.
The default value is 0.
12.3.3 RIP Options
Fig. 88: Routing ->RIP->RIP Options
The Routing -> RIP -> RIP Options menu consists of the following fields:
Fields in the RIP Options Global RIP Parameters menu
Field Description
RIP UDP Port The setting option UDP port, which is used for sending and re-
ceiving RIP updates, is only for test purposes. If the setting is
changed, this can mean that your device sends and listens at a
port that no other devices use. The default value 520 should be
retained.
Default Route Distribu- Select whether the default route of your device is to be propag-
Funkwerk Enterprise Communications GmbH
12 Routing
bintec W1002/W1002n/W2002/WIx040/WIx065 195

Table of Contents