Fig. 85: Routing ->RIP->RIP Interfaces->
The Routing->RIP->RIP Interfaces-> menu consists of the following fields:
Fields in the RIP Parameters for: <Interface> menu
Field Description
Send Version Decide whether routes are to be propagated via RIP and if so,
select the RIP version for sending RIP packets over the inter-
face in send direction.
Possible values:
• None (default value): RIP is not enabled.
• RIP V1: Enables sending and receiving of version 1 RIP
packets.
• RIP V2: Enables sending and receiving of version 2 RIP
packets.
• RIP V1/V2: Enables sending and receiving of both version 1
and version 2 RIP packets.
• RIP V2 Multicast: For sending RIP V2 messages over
the multicast address 224.0.0.9.
• RIP V1 Triggered: RIP V1 messages are sent, received
and processed as per RFC 2091 (triggered RIP).
• RIP V2 Triggered: RIP V2 messages are sent, received
and processed as per RFC 2091 (triggered RIP).
Funkwerk Enterprise Communications GmbH
12 Routing
bintec W1002/W1002n/W2002/WIx040/WIx065 191

Table of Contents

Other manuals for Funkwerk W1002

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Funkwerk W1002 and is the answer not in the manual?

Funkwerk W1002 Specifications

General IconGeneral
BrandFunkwerk
ModelW1002
CategoryWireless Access Point
LanguageEnglish

Related product manuals