Fig. 96: WAN->Real Time Jitter Control->Controlled Interfaces->New
The WAN->Real Time Jitter Control->Controlled Interfaces->New menu consists of the
following fields:
Fields in the Regulated InterfacesBasic Settings menu
Field Description
Interface In this field, you decide for which interfaces voice transmission
is to be optimised.
Control Mode Select the mode for the optimisation.
Possible values:
• Only Controlled RTP Streams(default value): By
means of the data routed via the media gateway, the system
detects voice data traffic and optimises the voice transmis-
sion.
• All RTP Streams: All RTP streams are optimised.
• Down : Voice data transmission is not optimised.
• Always: Voice data transmission is always optimised.
Maximum Upstream
Speed
Enter the maximum available upstream bandwidth in kbps for
the selected interface.