Field Description
• None (default value): Deactivates the sending of information
to the Activity Monitor.
• Physical: Only information about the physical interfaces is
sent.
• Physical/WAN/VPN: Information about physical and virtual
interfaces is sent
Send Information to Select where your device sends the UDP packets.
Possible values:
• All IP Addresses (broadcast) (default value): The de-
fault value 255.255.255.255 means that the broadcast ad-
dress of the first LAN interface is used.
• Single Host: The UDP packets are sent to the entered IP
address.
Update Interval Enter the update interval (in seconds).
Possible values are 0 to 60.
The default value is 5.
UDP Destination Port Enter the port number for the Windows application Activity
Monitor.
The default value is 2107 (registered by IANA - Internet As-
signed Numbers Authority).
Password Enter the password for the Activity Monitor.
18 External Reporting Funkwerk Enterprise Communications GmbH