7-2.4 System Initiated Dispatch Test
Sequence, Trunk II Si
gnaling
Configure the analyzer for trunk mode (paragraph
6-5) and System Initiated Testing (paragraph
6-7).
NOTE
Fleet, Subfleet, and Unit ID information
must be entered before the execution of a
System Initiated test. If a Radio Initiated test
is executed prior to the System Initiated test,
these fields are automatically updated. If
required, refer to paragraph 6-8.1 for in-
formation related to entry and storage of
system/fleet map configurations.
NOTE
SMARTZONE configures the analyzer to
perform a SMARTZONE affiliation
sequence prior to executing the dispatch test
sequence. If the radio is not capable of
SMARTZONE auto affiliation, the selection
should be set to DISABLED.
1. Enter the following parameters:
Sig Type: Trunk II
ID Disp: HEX or DEC
Call Seq: DISPATCH
2. Set the System ID to match the radio system
ID and one of the system IDs in the Radio
configuration screen in order to decode radio
ID information.
3. Enter Talk Group, Call Type, and Unit ID.
NOTE
If an announcement call type is selected, the
operator must also set the talk group to the
announcement talk group monitored by the
radio.
4. Enter the CCTx or Control Channel number.
Enter the VCTx or voice channel number.
NOTE
Splinter channels can only be entered by
frequency. Standard channels can be
entered by frequency or channel number
(channel numbers only map to standard
channel frequencies).
5. Set the monitor attenuation and port
selection. Suggested port selection is RF I/O
with 20 dB attenuation.
6. Set the generator attenuation and port
selection. Suggested port selection is RF I/O
with -50 dB for the level setting.
7. Press the start test softkey.
8. The status thermometer displays the major
signaling events that occur during a system
initiated Dispatch test. Refer to table 7-7
(Trunk II auto affiliation disabled), or
table 7-8 (Trunk II with auto affiliation).
115