General SEQ
Selects a free-form 20-tone sequence encoding
which has full flexibility to enter unique
frequency and time duration for each of the 20
tone slots. The single field below the "Format
Sel:" field is used to enter the frequency code
sequence. An expandable display table is
selectable by softkey to allow entry of frequency
and time duration data (figure 3-11). Frequencies
and durations are tabulated corresponding to a
given "code number" (i.e. 1], 2], 3], etc.).
Frequency and times are each selected inde-
pendently. This is done through entry of inde-
pendent "Code Sequence:" and "Dur Sequence:"
(for example, Code 1] may be selected along
with Dur 8] for the first tone slot in the se-
quence).
Tone Remote
Selects the specialized tone sequence used in
control of tone remote equipment. The frequen-
cies used are the same as those for the A/B
sequence with timing predetermined per
Motorola Tone Remote specifications. Changes
to the A and B frequencies can be made from the
A/B Sequence table or directly from the Tone A
and Tone B "Freq:" fields.
36