REMOTE CONTROL
223
Syntax
Query Syntax
MANU:ACW:ARCFunction
{OFF|ON_CONT|ON_STOP}
MANU:ACW:ARCFunction?
Parameter/
Return parameter
OFF
ARC function off
ON_CONT
ARC function ON & CONT
ON_STOP
ARC function ON & STOP
Example
MANU:ACW:ARCF OFF
Sets the ACW ARC function off.
MANU:ACW:ARCCurrent
Set
Query
Description
Sets or returns the ACW ARC current value in mA.
ARC must be enabled before the ARC current can
be set. The test must first be in ACW mode before
this command can be used.
Syntax
Query Syntax
MANU:ACW:ARCCurrent <NR2>
MANU:ACW:ARCCurrent?
Parameter/
Return parameter
<NR2>
1.000 ~ 80.00mA [GPT-12XXX]
1.000 ~ 200.0mA [GPT-15XXX]
Example
MANU:ACW:ARCC 1.233
Sets the ACW ARC value to 1.233 mA.
MANU:ACW:ARCSpeed
Set
Query
Description
Sets or returns the ACW ARC speed. ARC must be
enabled before the ARC speed can be set. The test
must first be in ACW mode before this command
can be used.
Syntax
Query Syntax
MANU:ACW:ARCSpeed {FAST|NORMAL|SLOW}
MANU:ACW:ARCSpeed?
Parameter/
Return parameter
FAST
ARC speed fast
NORMAL
ARC speed normal
SLOW
ARC speed slow

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GW Instek GPT-10000 Series and is the answer not in the manual?

GW Instek GPT-10000 Series Specifications

General IconGeneral
BrandGW Instek
ModelGPT-10000 Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals