EasyManua.ls Logo

GW Instek GPT-10000 Series - Manu:continuity:ttime; Manu:continuity:passhold

GW Instek GPT-10000 Series
288 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
REMOTE CONTROL
249
MANU:CONTinuity:TTIMe
Set
Query
Description
Sets or returns the CONT test time in seconds. The
test must first be in CONT mode before this
command can be used.
Syntax
Query Syntax
MANU:CONTinuity:TTIMe <NR2>
MANU:CONTinuity:TTIMe?
Parameter
<NR2>
0.3 ~ 999.9 seconds
Return parameter
<NR2>
0.3 ~ 999.9 seconds
Example
MANU:CONT:TTIM 1
Sets the CONT test time to 1 second.
MANU:CONTinuity:PASShold
Set
Query
Description
Sets or returns the duration of CONT PASS Hold.
The test must first be in CONT mode before this
command can be used.
Syntax
Query Syntax
MANU:CONTinuity:PASShold {<NR2>|ON}
MANU:CONTinuity:PASShold?
Parameter/
Return parameter
<NR2>
0 ~ 999.9 seconds
ON
Indefinite duration
Example
MANU:CONT:PASS 999.9
Sets the CONT PASS Hold time to 999.9 seconds.