REMOTE CONTROL
245
MANU:GB:FREQuency
Set
Query
Description
Sets or returns the GB test frequency in Hz. The
test must first be in GB mode before this command
can be used.
Syntax
Query Syntax
MANU:GB:FREQuency {50|60}
MANU:GB:FREQuency?
Parameter/
Return parameter
50
50 Hz
60
60 Hz
Example
MANU:GB:FREQ 50
Sets the GB test frequency to 50Hz.
MANU:GB:CONTact
Set
Query
Description
Sets or returns the GB Contact Time in seconds.
The test must first be in GB mode before this
command can be used.
Syntax
Query Syntax
MANU:GB:CONTact <NR2>
MANU:GB:CONTact?
Parameter/
Return parameter
<NR2>
0 ~ 999.9 seconds
Example
MANU:GB:CONTact 999.9
Sets the GB Contact time to 999.9 seconds.
MANU:GB:GROundmode
Set
Query
Description
Sets or returns the GB Ground Mode. The test
must first be in GB mode before this command can
be used.
Syntax
Query Syntax
MANU:GB:GROundmode {ON|OFF}
MANU:GB:GROundmode?
Parameter/
Return parameter
ON
GB Ground Mode ON
OFF
GB Ground Mode OFF

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GW Instek GPT-10000 Series and is the answer not in the manual?

GW Instek GPT-10000 Series Specifications

General IconGeneral
BrandGW Instek
ModelGPT-10000 Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals