11-37
Item Specifications
Efficiency at 50 % load 94%, 80 Plus platinum level
Temperature requirements
Operating temperature: 0°C to 50°C (32°F to 122°F)
Storage temperature: –40°C to +70°C (–40°F to +158°F)
Operating humidity 5% to 90%
Maximum altitude 5000 m (16404.20 ft)
Redundancy N+N redundancy
Hot swappable Yes
Cold backup Yes
850 W high-efficiency Platinum power supply
Item Specifications
Model DPS-850W-12A
Rated input voltage range
100 VAC to 240 VAC @ 50/60 Hz
192 VDC to 288 VDC (240 HVDC power source)
Maximum rated input current
10.0 A @ 100 VAC to 240 VAC
4.4 A @ 240 VDC
Maximum rated output power 850 W
Efficiency at 50 % load 94%, 80 Plus platinum level
Temperature requirements
Operating temperature: 0°C to 55°C (32°F to 131°F)
Storage temperature: –40°C to +70°C (–40°F to +158°F)
Operating humidity 5% to 85%
Maximum altitude 5000 m (16404.20 ft)
Redundancy N+N redundancy
Hot swappable Yes
Cold backup Yes
Expander modules
Model Specifications
DSD-EX-A-X Dual SD card extended module (supports RAID level 1)
BP-4SFF 4SFF SAS/SATA drive backplane
BP-4SFF-NVMe 4SFF NVMe drive backplane
PCIE-M2 PCIe M.2 SSD transfer module

Table of Contents

Other manuals for H3C UniServer R6900 G3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C UniServer R6900 G3 and is the answer not in the manual?

H3C UniServer R6900 G3 Specifications

General IconGeneral
BrandH3C
ModelUniServer R6900 G3
CategoryServer
LanguageEnglish

Related product manuals