11-36
Item Specifications
Efficiency at 50 % load 94%, 80 Plus platinum level
Temperature requirements
Operating temperature: 0°C to 50°C (32°F to 122°F)
Storage temperature: –40°C to +70°C (–40°F to +158°F)
Operating humidity 5% to 90%
Maximum altitude 5000 m (16404.20 ft)
Redundancy N+N redundancy
Hot swappable Yes
Cold backup Yes
1200 W power supply
Item Specifications
Model PSR1200-12A
Rated input voltage range
100 VAC to 127 VAC @ 50/60 Hz (1000 W)
200 VAC to 240 VAC @ 50/60 Hz (1200 W)
192 VDC to 288 VDC (240 HVDC power source) (1200 W)
Maximum rated input current
12.0 A @ 100 VAC to 240 VAC
6.0 A @ 240 VDC
Maximum rated output power 1200 W
Efficiency at 50 % load 94%, 80 Plus platinum level
Temperature requirements
Operating temperature: 0°C to 50°C (32°F to 122°F)
Storage temperature: –40°C to +70°C (–40°F to +158°F)
Operating humidity 5% to 90%
Maximum altitude 5000 m (16404.20 ft)
Redundancy N+N redundancy
Hot swappable Yes
Cold backup Yes
1600 W power supply
Item Specifications
Model PSR850-12A
Rated input voltage range
200 VAC to 240 VAC @ 50/60 Hz
192 VDC to 288 VDC (240 HVDC power source)
Maximum rated input current
9.5 A @ 200 VAC to 240 VAC
8.0 A @ 240 VDC
Maximum rated output power 1600 W

Table of Contents

Other manuals for H3C UniServer R6900 G3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C UniServer R6900 G3 and is the answer not in the manual?

H3C UniServer R6900 G3 Specifications

General IconGeneral
BrandH3C
ModelUniServer R6900 G3
CategoryServer
LanguageEnglish

Related product manuals