Touch probe cycles | General information on touch probe cycles (software option)
5
HEIDENHAIN | User's Manual smart.Turn and DIN Programming | 12/2017
521
Touch probe cycles for automatic mode
The control provides numerous touch probe cycles for various
applications:
Calibrating a touch trigger probe
Measuring circles, circle segments, angle and position of the C
axis
Misalignment compensation
Single-point and double-point measurement
Finding a hole or stud
Datum setting in the Z or C axis
Automatic tool measurement
Touch probe cycles are programmed in the smart.Turn operating
mode using the G codes. Just like the fixed cycles, the touch probe
cycles also use transfer parameters.
To simplify programming, the control shows a graphic during cycle
definition. The appropriate input parameters are displayed in the
help graphic.
The touch probe cycles save status information and measuring
results in the variable #i99.
Depending on the input parameters in the touch probe cycle you
can interrogate various values.
Result #i99
Meaning
< 999997 Measuring result
999999 Touch probe not deflected
-999999 Invalid measuring axis
programmed
999998
Max. deviation WE exceeded
999997
Maximum perm. correction E
exceeded
Programming the touch probe cycle in ISO Mode:
Select ISO Mode programming and place the
cursor in the MACHINING program section
Select the Mach» menu item
Select the G-menu menu item
Select the Touch probe cycles menu item
Select measuring cycle group
Select the cycle