System Operation
3-65
GNS-XLS Flight Management System
Rev. 3
Sep/96
Selecting Exit Mode:
10. Line Select Key - DE-
PRESS to position the
cursor over MANUAL or
AUTO. Press the BACK
key to change exit mode
option. Selecting MANU-
AL will initiate a continu-
ous hold. Selecting
AUTO will exit the hold
the next time the HP fix is
crossed or after the entry
procedure is completed.
(Figure 3-109)
11. ENTER Key - DEPRESS. OK? ENTER prompt will appear. Verify
inputs.
12. ENTER Key - DEPRESS to load the Holding Pattern at the selected
waypoint and return to the NAVIGATION, DIRECT TO, or FPL
Page.
REVIEWING, EDITING, OR CANCELING A HOLDING PATTERN
This procedure enables the pilot to review, edit, or cancel a Holding
Pattern at a specific waypoint.
REVIEWING
1. NAV, FPL, or d Key - DEPRESS to display applicable page.
2. Line Select Key - DEPRESS to position the cursor over desired HP
waypoint.
NOTE: On NAVIGATION Pages, only the TO Waypoint can be select-
ed, and on the Active Flight
Plan, the TO Waypoint can
only be reviewed.
3. HOLD Key - DEPRESS
to display HOLDING
PATTERN Page. (Figure
3-110)
4. Holding Pattern - REVIEW.
AT TRM (USA)
DIRECT ENTRY
INBOUND CRS 013
MAX HOLDING TAS 259
TURN DIR RIGHT
LEG TIME 1.0
LEG DIS (3.2)
EXIT MODE MANUAL
OK? ENTER
HOLDING PATTERN 1/1
>
>
>
>
Figure 3-109
AT TRM (USA)
DIRECT ENTRY
INBOUND CRS 013
MAX HOLDING TAS
TURN DIR RIGHT
LEG TIME 1.0
LEG DIS (3.2)
EXIT MODE MANUAL
OK? ENTER CANCEL
HOLDING PATTERN 1/1
>
>
>
>
Figure 3-110