APPENDIX B
Event and Alarm Types
242 MAXPRO NVR 3.1 Operator’s Guide
B
Event and Alarm Types
This section describes about the various default Event and Alarm types with severity level for
Camera , Recorder and Smart VMD.
Camera Level Events and Alarm types
The following table displays the 17 default camera level Events and Alarm types with
description and severity level.
Note: The EventSeverity level above 50 is an alarm and below 50 is an event. See
Setting the Alarm Threshold Value section to set the Alarm Severity Threshold
value.
Recorder Level Events and Alarm types
The following table displays the 4 default Recorder level Events and Alarm types with
description and severity level.
EventID EventDescription EventSeverity
3 Camera User Recording Started 20
4 Camera User Recording Completed 20
5 Camera Disconnected 40
6 Camera Connected 40
7 Camera Continuous Recording Disabled 20
8 Camera Continuous Recording Enabled 20
9 Camera Event Recording Started 30
10 Camera Event Recording Completed 30
11 Camera Disabled 20
12 Camera Enabled 20
13 Camera User Recording Error 30
14 Camera NoMotion Detected 50
15 Camera Motion Detected 50
16 Camera Motion Started 70
17 Camera Motion Stopped 40
18 Camera Motion Stopped in all regions 10
139 ExternalInput2 40
EventID EventDescription EventSeverity
1 Recorder Connected 70
2 Recorder Disconnected 70