EasyManuals Logo

HP Integrity rx6600 Service Manual

HP Integrity rx6600
348 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #103 background imageLoading...
Page #103 background image
An IM array must have exactly two disks.
A hot spare disk cannot be created without at least one IM volume already created.
The utility does not allow adding a hot spare disk of type different from disk types in any of
the volume.
With the AUTO command all drives used are the same type as the first available disk found,
and the size is limited to the size of the smallest disk.
CFGGEN Commands
Using the CREATE Command
The create command creates IM volumes on the SAS controller. Firmware and hardware limitations
for this family of cards limit the number of configurations that are possible.
Syntax
cfggen <controller #> create <volume type> <size> [qsync] [noprompt]
Parameters
<volume type> Volume type for the volume to be created. Valid value is IM.
<size> Size of the IM volume in Mbytes or “MAX” for the maximum size available.
[qsync] Quick synchronization of the volume created.
[noprompt] Eliminates warnings and prompts.
Operation
Once a disk has been added to an IM volume, all of its storage capacity may or may not be used
depending on drive capacity and volume capacity. For example, if you add a 36 GB disk drive
to a volume that only uses 9 GB of capacity on each disk drive, the remaining 27 GB of capacity
on the disk drive is unusable.
The disk identified by the first SCSI ID on the command line is assigned as the primary disk drive
when creating an IM volume. If the SAS controller is allowed to resync the disk drives, the data
on the primary disk drive is available by accessing the newly created volume.
Using the AUTO Command
The AUTO command automatically creates an IM volume on the SAS controllers. The volume is
created with the maximum number of disks available for use in the specified volume type. The
main difference from the CREATE command is that with AUTO command user does not specify
SCSI ID values for disks to use in the volume. The cfggen utility automatically uses the first disks
it finds that are usable in the IM volume. Firmware and hardware limitations for the family of
controllers limit the number of configurations that are possible.
Syntax
cfggen <controller #> auto <volume type> <size> [qsync] [noprompt]
Parameters
<volume type> Volume type for the volume to be created. Valid value is IM.
<size> Size of the RAID volume in Mbytes or “MAX” for the maximum size available.
[qsync] Quick synchronization of the volume created.
[noprompt] Eliminates warnings and prompts.
Core I/O Card Configuration 103

Table of Contents

Other manuals for HP Integrity rx6600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP Integrity rx6600 and is the answer not in the manual?

HP Integrity rx6600 Specifications

General IconGeneral
ProcessorIntel Itanium 2
NetworkIntegrated dual Gigabit Ethernet
Form Factor5U rack-mountable
Power SupplyRedundant hot-plug power supplies
Processor Speed1.6 GHz
Memory TypeDDR2 ECC Registered
RAID SupportYes
Operating SystemHP-UX, Linux, Windows Server

Related product manuals