EasyManuals Logo

HP Integrity rx6600 Service Manual

HP Integrity rx6600
348 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #163 background imageLoading...
Page #163 background image
Table 57 I/O Power Events That Light Diagnostic Panel LEDs
NotesSourceCauseSample IPMI EventsDiagnostic
LEDs
A voltage on
the I/O
BMCVoltage
on CRU
Type 02h, 02h:07h:03h
VOLTAGE_DEGRADES_TO_NON_RECOVERABLE
I/O Power
poweris
inadequate assembly is
out of range
(likely too
low)
Cooling Subsystem
There are six fan cooling zones within the server chassis that provide N+1 rotor redundancy for
the chassis using six identical dual fan assembly CRUs. Each dual fan assembly CRU is identified
by the chassis as fan 1-6 both for logging purposes and for fault identification. Note, however,
that three of the six total dual fan assemblies are considered as internal CRUs and are identified
by the chassis as fans 1, 2, and 3 on the diagnostic LED panel while the other three dual fan are
considered as external CRUs identified as fans 4, 5, and 6 and do not have LEDs on the diagnostic
LED panel.
External cooling fan CRU failures are identified visually by a single green LED on the dual fan
assembly CRU that is turned on when one or both of the fans fail; logged as an IPMI event by fan
sensor logic; and identified as a fan assembly CRU failure by the BMC turning on the appropriate
LEDs on the front and diagnostic LED panels.
Cooling Subsystem Behavior
The baseboard Management Controller (BMC) chip located on the Unified Core I/O board CRU
controls fan speed on ambient air temperatures, chip temperatures, server configuration, and fan
operation or failure. Air is drawn through the front of the chassis and pushed out the rear by the
cooling fans. (Note that you can display fan status remotely with the iLO 2 MP ps command.)
Within the server, temperature sensors report chassis temperatures to the BMC, which controls fan
speed based on this information.
Table 58 lists the cooling subsystem events that light the diagnostic panel LEDs.
Table 58 Cooling Subsystem Events That Light Diagnostic Panel LEDs
NotesSourceCauseSample IPMI EventsDiagnostic
LEDs
Cleared when fan is
replaced
BMCFan has either
previously failed or
is degrading
Type 02h, 0Ah:07h:01h
COOLING_UNIT_WARNING
Fans (1-3)
Cleared when fan is
replaced
BMCFan has failed and
no longer meets
Type 02h, 0Ah:07h:02h
COOLING_UNIT_FAILURE
Fans (1-3)
minimum
requirements
Common I/O Backplane (LBAs/Ropes/PDH/PCI-X Slots)
This subsection provides information on troubleshooting issues with the 8 public and 2 private
PCI-X slots.
I/O Subsystem Behaviors
The main role of the I/O subsystem is to transfer blocks of data and instruction words between
physical shared memory and virtual memory (system disks / disk array). The system boot is the
first time blocks of data and instructions words are transferred into physical shared memory from
Cooling Subsystem 163

Table of Contents

Other manuals for HP Integrity rx6600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP Integrity rx6600 and is the answer not in the manual?

HP Integrity rx6600 Specifications

General IconGeneral
ProcessorIntel Itanium 2
NetworkIntegrated dual Gigabit Ethernet
Form Factor5U rack-mountable
Power SupplyRedundant hot-plug power supplies
Processor Speed1.6 GHz
Memory TypeDDR2 ECC Registered
RAID SupportYes
Operating SystemHP-UX, Linux, Windows Server

Related product manuals