Page #179 background image
Figure 55 Removing and Replacing the Top Cover
Replacing the Top Cover
NOTE: Replace the memory carrier assembly cover before replacing the top cover.
To replace the top cover, follow these steps:
1. Ensure the cover release lever is in the open position (Figure 55).
2. Align the tabs of the top cover with the corresponding slots in the chassis and insert the tabs
into the slots.
3. Slide the cover forward until it is flush with the front of the chassis.
4. Push the cover release lever down into the latched position (Figure 55).
5. Lock the cover release lever by turning the cam approximately 90 degrees clockwise.
Removing and Replacing the Memory Carrier Assembly Cover
Use the following procedures to remove and replace the memory carrier assembly cover.
NOTE: When the memory carrier assembly cover is open or removed, the chassis fan units
increase to high speed to assist cooling. When the top cover is replaced at the end of the operation,
the chassis fan units return to normal speed.
Removing the Memory Carrier Assembly Cover
To remove the memory carrier assembly cover, follow these steps:
Removing and Replacing the Memory Carrier Assembly Cover 179

Table of Contents

Other manuals for HP Integrity rx6600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP Integrity rx6600 and is the answer not in the manual?

HP Integrity rx6600 Specifications

General IconGeneral
ProcessorIntel Itanium 2
NetworkIntegrated dual Gigabit Ethernet
Form Factor5U rack-mountable
Power SupplyRedundant hot-plug power supplies
Processor Speed1.6 GHz
Memory TypeDDR2 ECC Registered
RAID SupportYes
Operating SystemHP-UX, Linux, Windows Server

Related product manuals