3 HARDDRIVE
Acpi(HWP0002,PNP0A03,400)/Pci(2|0)/Sas(Addr5000C50000347735,Lun0)/HD(Part1,Sig92C8CB4C-E0F2-11DA-8002-D6217B60E588)
4 HARDDRIVE
Acpi(HWP0002,PNP0A03,400)/Pci(2|0)/Sas(Addr5000C50000347735,Lun0)/HD(Part3,Sig92C8CB7E-E0F2-11DA-8004-D6217B60E588)
Seg Bus Dev Fnc Vendor Device Slot
# # # # ID ID # Path
--- --- --- --- ------ ------ --- -----------
00 00 01 00 0x103C 0x1303 XX Acpi(HWP0002,PNP0A03,0)/Pci(1|0)
00 00 01 01 0x103C 0x1302 XX Acpi(HWP0002,PNP0A03,0)/Pci(1|1)
00 00 01 02 0x103C 0x1048 XX Acpi(HWP0002,PNP0A03,0)/Pci(1|2)
00 00 02 00 0x1033 0x0035 XX Acpi(HWP0002,PNP0A03,0)/Pci(2|0)
00 00 02 01 0x1033 0x0035 XX Acpi(HWP0002,PNP0A03,0)/Pci(2|1)
00 00 02 02 0x1033 0x00E0 XX Acpi(HWP0002,PNP0A03,0)/Pci(2|2)
00 14 01 00 0x1000 0x0054 01 Acpi(HWP0002,PNP0A03,400)/Pci(1|0)
00 14 02 00 0x1000 0x0054 02 Acpi(HWP0002,PNP0A03,400)/Pci(2|0)
00 15 01 00 0x1000 0x000F 07 Acpi(HWP0002,PNP0A03,500)/Pci(1|0)
00 15 01 01 0x1000 0x000F 07 Acpi(HWP0002,PNP0A03,500)/Pci(1|1)
00 15 02 00 0x8086 0x1079 08 Acpi(HWP0002,PNP0A03,500)/Pci(2|0)
00 15 02 01 0x8086 0x1079 08 Acpi(HWP0002,PNP0A03,500)/Pci(2|1)
Fast initialization: Enabled
System Wake-On-LAN: Enabled
Shell>
Devices, such as USB ports, that do not occupy a slot are referenced as being in slot XX. Slots
that do not contain an I/O card will not be listed in the output. Using the output, confirm that
a device detected in each slot that is populated.
13. Installing the OS
HP-UX, Windows, and Linux require reinstallation of the OS with the upgrade of the IOBP.
See Figure 89 (page 258) for more information.
14. Booting to the Operating System
See Chapter 4 (page 118) for this procedure.
Installing Core I/O Cards
WARNING! To reduce the risk of personal injury from hot surfaces, allow the internal system
components to cool before touching them.
CAUTION: To reduce the risk of personal injury or damage to the equipment, consult the safety
information and user documentation provided with the server before attempting the installation.
Many servers are capable of producing energy levels that are considered hazardous and are
intended to be serviced only by qualified personnel who have been trained to deal with these
hazards. Do not remove enclosures or attempt to bypass any interlocks that may be provided for
the purpose of removing these hazardous conditions.
CAUTION: Electrostatic discharge (ESD) can damage electronic components. Be sure that you
are properly grounded before beginning this procedure.
CAUTION: When working with equipment installed in a rack, be sure that the equipment and
rack are stable before beginning the installation procedure.
Slots 1 and 2 are dedicated for the PCI-X core I/O cards. The LAN core I/O card is installed either
in slot 2 or slot 10 depending on the configuration. PCIe SAS core I/O cards are installed in slots
3 or 4 on the PCIe I/O backplane.
Cabling
The cables that are required to connect the adapters and controllers to other devices are provided
with most HP server products that need them. Table 82 lists some cables that can be used with
these adapters and controllers. All HP cables are keyed so that they cannot be installed incorrectly.
Installing Core I/O Cards 263

Table of Contents

Other manuals for HP Integrity rx6600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP Integrity rx6600 and is the answer not in the manual?

HP Integrity rx6600 Specifications

General IconGeneral
ProcessorIntel Itanium 2
NetworkIntegrated dual Gigabit Ethernet
Form Factor5U rack-mountable
Power SupplyRedundant hot-plug power supplies
Processor Speed1.6 GHz
Memory TypeDDR2 ECC Registered
RAID SupportYes
Operating SystemHP-UX, Linux, Windows Server