8-3
Time Protocols
Overview: Selecting a Time Synchronization Protocol or Turning Off Time Protocol Operation
ular server, it ignores time broadcasts from other SNTP servers unless
the configurable
Poll Interval expires three consecutive times without
an update received from the first-detected server.
Note
To use Broadcast mode, the switch and the SNTP server must be in the
same subnet.
Unicast Mode: The switch requests a time update from the config-
ured SNTP server. (You can configure one server using the menu
interface, or up to three servers using the CLI
sntp server command.)
This option provides increased security over the Broadcast mode by
specifying which time server to use instead of using the first one
detected through a broadcast.
Overview: Selecting a Time
Synchronization Protocol or Turning Off
Time Protocol Operation
General Steps for Running a Time Protocol on the Switch:
1. Select the time synchronization protocol: SNTP or TimeP (the default).
2. Enable the protocol. The choices are:
SNTP:
Broadcast or Unicast
•TimeP: DHCP or Manual
3. Configure the remaining parameters for the time protocol you selected.
The switch retains the parameter settings for both time protocols even if
you change from one protocol to the other. Thus, if you select a time
protocol, the switch uses the parameters you last configured for the
selected protocol.
!Software.book Page 3 Thursday, October 10, 2002 6:10 PM

Table of Contents

Other manuals for HP ProCurve 2650

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve 2650 and is the answer not in the manual?

HP ProCurve 2650 Specifications

General IconGeneral
Switching Capacity13.6 Gbps
Forwarding Rate10.1 Mpps
Layer2
Jumbo Frame SupportYes
Form FactorRack-mountable
VLAN SupportYes
Layer 3 RoutingNo
PoE SupportNo
FanlessNo
AltitudeUp to 3, 000 meters
ManagementCLI, SNMP
Operating Temperature0°C to 50°C
Storage Temperature-40°C to 70°C
Humidity15% to 95% non-condensing

Related product manuals