11-41
Port-Based Virtual LANs (VLANs) and GVRP
GVRP
Planning for GVRP Operation
These steps outline the procedure for setting up dynamic VLANs for a seg-
ment.
1. Determine the VLAN topology you want for each segment (broadcast
domain) on your network.
2. Determine the VLANs that must be static and the VLANs that can be
dynamically propagated.
3. Determine the device or devices on which you must manually create static
VLANs in order to propagate VLANs throughout the segment.
4. Determine security boundaries and how the individual ports in the seg-
ment will handle dynamic VLAN advertisements. (See table 11-11-3 on
page 11-37 and table 11-11-4 on page 11-39.)
5. Enable GVRP on all devices you want to use with dynamic VLANs and
configure the appropriate “Unknown VLAN” parameter (Learn, Block, or
Disable) for each port.
6. Configure the static VLANs on the switch(es) where they are needed,
along with the per-VLAN parameters (Tagged, Untagged, Auto, and Forbid
see table 11-11-4 on page 11-39) on each port.
7. Dynamic VLANs will then appear automatically, according to the config-
uration options you have chosen.
8. Convert dynamic VLANs to static VLANs where you want dynamic VLANs
to become permanent.
Configuring GVRP On a Switch
The procedures in this section describe how to:
View the GVRP configuration on a switch
Enable and disable GVRP on a switch
Specify how individual ports will handle advertisements
To view or configure static VLANs for GVRP operation, refer to “Per-Port Static
VLAN Configuration Options” on page 11-8.
!Software.book Page 41 Thursday, October 10, 2002 6:10 PM

Table of Contents

Other manuals for HP ProCurve 2650

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve 2650 and is the answer not in the manual?

HP ProCurve 2650 Specifications

General IconGeneral
Switching Capacity13.6 Gbps
Forwarding Rate10.1 Mpps
Layer2
Jumbo Frame SupportYes
Form FactorRack-mountable
VLAN SupportYes
Layer 3 RoutingNo
PoE SupportNo
FanlessNo
AltitudeUp to 3, 000 meters
ManagementCLI, SNMP
Operating Temperature0°C to 50°C
Storage Temperature-40°C to 70°C
Humidity15% to 95% non-condensing