11-44
Port-Based Virtual LANs (VLANs) and GVRP
GVRP
Enabling and Disabling GVRP on the Switch. This command enables
GVRP on the switch.
Syntax: gvrp
This example enables GVRP:
HPswitch(config)# gvrp
This example disables GVRP operation on the switch:
HPswitch(config)# no gvrp
Enabling and Disabling GVRP On Individual Ports. When GVRP is
enabled on the switch, use the unknown-vlans command to change the
Unknown VLAN field for one or more ports. You can use this command at
either the Manager level or the interface context level for the desired port(s).
Syntax: interface <port-list> unknown-vlans Changes the Unknown VLAN
<learn | block | disable> field setting for the specified
port(s).
For example, to change and view the configuration for ports A1-A2 to Block:
Figure 11-31. Example of Preventing Specific Ports from Joining Dynamic VLANs
!Software.book Page 44 Thursday, October 10, 2002 6:10 PM

Table of Contents

Other manuals for HP ProCurve 2650

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve 2650 and is the answer not in the manual?

HP ProCurve 2650 Specifications

General IconGeneral
Switching Capacity13.6 Gbps
Forwarding Rate10.1 Mpps
Layer2
Jumbo Frame SupportYes
Form FactorRack-mountable
VLAN SupportYes
Layer 3 RoutingNo
PoE SupportNo
FanlessNo
AltitudeUp to 3, 000 meters
ManagementCLI, SNMP
Operating Temperature0°C to 50°C
Storage Temperature-40°C to 70°C
Humidity15% to 95% non-condensing

Related product manuals