Page #432 background image
A-16
File Transfers
Copying Diagnostic Data to a Remote Host, PC, or Unix Workstation
Copying Diagnostic Data to a Remote
Host, PC, or Unix Workstation
You can use the CLI to copy the following types of switch data to a text file in
a management device:
Command Output: Sends the output of a switch CLI command as a file on
the destination device.
Event Log: Copies the switchs Event Log into a file on the destination
device.
Crash Data: OS-specific data useful for determining the reason for a
system crash.
Crash Log: Processor-Specific operating data useful for determining the
reason for a system crash.
Copying Command Output to a Destination Device
This command directs the displayed output of a CLI command to a file in a
destination device.
Syntax: copy command-output <cli-command> tftp <ip-address>
<filepath-filename>
copy command-output <cli-command> xmodem
For example, to use Xmodem to copy the output of show config to a serially
connected PC:
Figure A-8. Example of Sending Command Output to a File on an Attached PC
Note that the command you specify must be enclosed in double-quote marks.
At this point, press
and start the
Xmodem command
sequence in your
terminal emulator.
Indicates the operation is finished.
!Software.book Page 16 Thursday, October 10, 2002 6:10 PM

Table of Contents

Other manuals for HP ProCurve 2650

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve 2650 and is the answer not in the manual?

HP ProCurve 2650 Specifications

General IconGeneral
Switching Capacity13.6 Gbps
Forwarding Rate10.1 Mpps
Layer2
Jumbo Frame SupportYes
Form FactorRack-mountable
VLAN SupportYes
Layer 3 RoutingNo
PoE SupportNo
FanlessNo
AltitudeUp to 3, 000 meters
ManagementCLI, SNMP
Operating Temperature0°C to 50°C
Storage Temperature-40°C to 70°C
Humidity15% to 95% non-condensing

Related product manuals