8-13
Time Protocols
TimeP: Viewing, Selecting, and Configuring
Disabling the SNTP Mode. If you want to prevent SNTP from being used
even if selected by
timesync (or the Menu interfaces Time Sync Method param-
eter), configure the SNTP mode as disabled.
Syntax: no sntp Disables SNTP by changing the SNTP mode
configuration to Disabled.
For example, if the switch is running SNTP in Unicast mode with an SNTP
server at 10.28.227.141 and a server version of 3 (the default),
no sntp changes
the SNTP configuration as shown below, and disables time synchronization
on the switch.
Figure 8-8. Example of Disabling Time Synchronization by Disabling the SNTP Mode
TimeP: Viewing, Selecting, and
Configuring
Even though the Time Sync Mode is set to Sntp,
time synchronization is disabled because no
sntp has disabled the SNTP Mode parameter.
TimeP Feature Default Menu CLI Web
view the Timep time synchronization configuration n/a page 8-14 page 8-16
select Timep as the time synchronization method TIMEP page 8-13 pages 8-17
ff.
disable time synchronization timep page 8-15 page 8-19
enable the Timep mode Disabled
DHCP page 8-15 page 8-17
manual page 8-15 page 8-18
none/disabled page 8-15 page 8-20
change the SNTP poll interval 720 minutes page 8-16 page 8-19
!Software.book Page 13 Thursday, October 10, 2002 6:10 PM

Table of Contents

Other manuals for HP ProCurve 2650

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve 2650 and is the answer not in the manual?

HP ProCurve 2650 Specifications

General IconGeneral
Switching Capacity13.6 Gbps
Forwarding Rate10.1 Mpps
Layer2
Jumbo Frame SupportYes
Form FactorRack-mountable
VLAN SupportYes
Layer 3 RoutingNo
PoE SupportNo
FanlessNo
AltitudeUp to 3, 000 meters
ManagementCLI, SNMP
Operating Temperature0°C to 50°C
Storage Temperature-40°C to 70°C
Humidity15% to 95% non-condensing

Related product manuals