C-24
Troubleshooting
Using the Event Log To Identify Problem Sources
CLI:
Using the CLI, you can list
Events recorded since the last boot of the switch
All events recorded
Event entries containing a specific keyword, either since the last boot or
all events recorded
Syntax: show logging [-a] [<search-text>]
HPswitch> show logging
Lists recorded log messages since
last reboot.
HPswitch> show logging -a
Lists all recorded log messages,
including those before the last
reboot.
HPswitch> show logging -a system
Lists log messages with "system"
in the text or modulename.
HPswitch> show logging system
Lists all log messages since the
last reboot that have system in
the text or module name.
!Software.book Page 24 Thursday, October 10, 2002 6:10 PM

Table of Contents

Other manuals for HP ProCurve 2650

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve 2650 and is the answer not in the manual?

HP ProCurve 2650 Specifications

General IconGeneral
Switching Capacity13.6 Gbps
Forwarding Rate10.1 Mpps
Layer2
Jumbo Frame SupportYes
Form FactorRack-mountable
VLAN SupportYes
Layer 3 RoutingNo
PoE SupportNo
FanlessNo
AltitudeUp to 3, 000 meters
ManagementCLI, SNMP
Operating Temperature0°C to 50°C
Storage Temperature-40°C to 70°C
Humidity15% to 95% non-condensing