Monitoring and Analyzing Switch Operation
Port and Static Trunk Monitoring Features
CLI: Configuring Port and Static Trunk Monitoring
Port and Static Trunk Monitoring Commands Used in This Section
You must use the following configuration sequence to configure port and static
trunk monitoring in the CLI:
1. Assign a monitoring (mirror) port.
2. Designate the port(s) and static trunk(s) to monitor.
Displaying the Monitoring Configuration. This command lists the port
assigned to receive monitored traffic and the ports and/or trunks being
monitored.
Syntax: show monitor
For example, if you assign port A6 as the monitoring port and configure the
switch to monitor ports A1 - A3, show monitor displays the following:
Figure B-20. Example of Monitored Port Listing
Configuring the Monitor Port. This command assigns or removes a mon-
itoring port, and must be executed from the global configuration level. Remov-
ing the monitor port disables port monitoring and resets the monitoring
parameters to their factory-default settings.
Syntax: [no] mirror-port [< port-num >]
For example, to assign port A6 as the monitoring port:
HPswitch(config)# mirror-port a6
show monitor
mirror-port
monitor
below
page B-26
page B-27
Port receiving monitored traffic.
Monitored Ports
!Software.book Page 26 Thursday, October 10, 2002 6:10 PM

Table of Contents

Other manuals for HP ProCurve 2650

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve 2650 and is the answer not in the manual?

HP ProCurve 2650 Specifications

General IconGeneral
Switching Capacity13.6 Gbps
Forwarding Rate10.1 Mpps
Layer2
Jumbo Frame SupportYes
Form FactorRack-mountable
VLAN SupportYes
Layer 3 RoutingNo
PoE SupportNo
FanlessNo
AltitudeUp to 3, 000 meters
ManagementCLI, SNMP
Operating Temperature0°C to 50°C
Storage Temperature-40°C to 70°C
Humidity15% to 95% non-condensing