Unusual Network Activity
For more help, refer to the documentation provided with your TACACS+
server application.
Unknown Users Allowed to Login to the Switch. Your TACACS+ appli-
cation may be configured to allow access to unknown users by assigning them
the privileges included in a default user profile. Refer to the documentation
provided with your TACACS+ server application.
System Allows Fewer Login Attempts than Specified in the Switch
Configuration. Your TACACS+ server application may be configured to
allow fewer login attempts than you have configured in the switch with the
aaa authentication num-attempts command.
TimeP, SNTP, or Gateway Problems
The Switch Cannot Find the Time Server or the Configured Gateway .
TimeP, SNTP, and Gateway access are through the primary VLAN, which in
the default configuration is the DEFAULT_VLAN. If the primary VLAN has
been moved to another VLAN, it may be disabled or does not have ports
assigned to it.
VLAN-Related Problems
Monitor Port. When using the monitor port in a multiple VLAN environ-
ment, the switch handles broadcast, multicast, and unicast traffic output from
the monitor port as follows:
If the monitor port is configured for tagged VLAN operation on the same
VLAN as the traffic from monitored ports, the traffic output from the
monitor port carries the same VLAN tag.
If the monitor port is configured for untagged VLAN operation on the same
VLAN as the traffic from the monitored ports, the traffic output from the
monitor port is untagged.
If the monitor port is not a member of the same VLAN as the traffic from
the monitored ports, traffic from the monitored ports does not go out the
monitor port.
None of the devices assigned to one or more VLANs on an 802.1Q-
compliant switch are being recognized. If multiple VLANs are being used
on ports connecting 802.1Q-compliant devices, inconsistent VLAN IDs may
have been assigned to one or more VLANs. For a given VLAN, the same VLAN
ID must be used on all connected 802.1Q-compliant devices.
!Software.book Page 18 Thursday, October 10, 2002 6:10 PM

Table of Contents

Other manuals for HP ProCurve 2650

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve 2650 and is the answer not in the manual?

HP ProCurve 2650 Specifications

General IconGeneral
Switching Capacity13.6 Gbps
Forwarding Rate10.1 Mpps
Layer2
Jumbo Frame SupportYes
Form FactorRack-mountable
VLAN SupportYes
Layer 3 RoutingNo
PoE SupportNo
FanlessNo
AltitudeUp to 3, 000 meters
ManagementCLI, SNMP
Operating Temperature0°C to 50°C
Storage Temperature-40°C to 70°C
Humidity15% to 95% non-condensing