Troubleshooting
Unusual Network Activity
The authorized MAC address on a port that is configured for both
802.1x and port security either changes or is re-acquired after
execution of
aaa port-access authenticator < port-list > initialize. If the port is
force-authorized with
aaa port-access authenticator <port-list> control authorized com-
mand and port security is enabled on the port, then executing
initialize causes
the port to clear the learned address and learn a new address from the first
packet it receives after you execute
initialize.
A trunked port configured for 802.1x is blocked. If you are using
RADIUS authentication and the RADIUS server specifies a VLAN for the port,
the switch allows authentication, but blocks the port. To eliminate this prob-
lem, either remove the port from the trunk or reconfigure the RADIUS server
to avoid specifying a VLAN.
Radius-Related Problems
The switch does not receive a response to RADIUS authentication
requests. In this case, the switch will attempt authentication using the
secondary method configured for the type of access you are using (console,
Telnet, or SSH).
There can be several reasons for not receiving a response to an authentication
request. Do the following:
Use ping to ensure that the switch has access to the configured RADIUS
server.
Verify that the switch is using the correct encryption key for the desig-
nated server.
Verify that the switch has the correct IP address for the RADIUS server.
Ensure that the radius-server timeout period is long enough for network
conditions.
Verify that the switch is using the same UDP port number as the server.
RADIUS server fails to respond to a request for service, even though
the servers IP address is correctly configured in the switch. Use
show radius to verify that the encryption key the switch is using is correct for
the server being contacted. If the switch has only a global key configured, then
it either must match the server key or you must configure a server-specific
key. If the switch already has a server-specific key assigned to the servers IP
address, then it overrides the global key and must match the server key.
!Software.book Page 12 Thursday, October 10, 2002 6:10 PM

Table of Contents

Other manuals for HP ProCurve 2650

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve 2650 and is the answer not in the manual?

HP ProCurve 2650 Specifications

General IconGeneral
Switching Capacity13.6 Gbps
Forwarding Rate10.1 Mpps
Layer2
Jumbo Frame SupportYes
Form FactorRack-mountable
VLAN SupportYes
Layer 3 RoutingNo
PoE SupportNo
FanlessNo
AltitudeUp to 3, 000 meters
ManagementCLI, SNMP
Operating Temperature0°C to 50°C
Storage Temperature-40°C to 70°C
Humidity15% to 95% non-condensing