Troubleshooting
Unusual Network Activity
Figure C-1. Example of a Port Remaining Open After Being Configured with "Control Unauthorized"
RADIUS server fails to respond to a request for service, even though
the servers IP address is correctly configured in the switch. Use
show radius to verify that the encryption key (RADIUS secret key) the switch
is using is correct for the server being contacted. If the switch has only a global
key configured, then it either must match the server key or you must configure
a server-specific key. If the switch already has a server-specific key assigned
to the servers IP address, then it overrides the global key and must match the
server key.
Also, ensure that the switch port used to access the RADIUS server is not
blocked by an 802.1x configuration on that port. For example,
show port-access
authenticator < port-list
> gives you the status for the specified ports. Also, ensure
that other factors, such as port security or any 802.1x configuration on the
RADIUS server are not blocking the link.
Port A9 shows an Open status even
though Access Control is set to
Unauthorized (Force Auth). This is
because the port-access
authenticator has not yet been
activated.
Global RADIUS Encryption Key
Unique RADIUS Encryption Key
for the RADIUS server at
10.33.18.119
!Software.book Page 11 Thursday, October 10, 2002 6:10 PM

Table of Contents

Other manuals for HP ProCurve 2650

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve 2650 and is the answer not in the manual?

HP ProCurve 2650 Specifications

General IconGeneral
Switching Capacity13.6 Gbps
Forwarding Rate10.1 Mpps
Layer2
Jumbo Frame SupportYes
Form FactorRack-mountable
VLAN SupportYes
Layer 3 RoutingNo
PoE SupportNo
FanlessNo
AltitudeUp to 3, 000 meters
ManagementCLI, SNMP
Operating Temperature0°C to 50°C
Storage Temperature-40°C to 70°C
Humidity15% to 95% non-condensing