C-10
Troubleshooting
Unusual Network Activity
Ensure that the radius-server timeout period is long enough for network
conditions.
The switch does not authenticate a client even though the RADIUS
server is properly configured and providing a response to the
authentication request. If the RADIUS server configuration for authenti-
cating the client includes a VLAN assignment, ensure that the VLAN exists as
a static VLAN on the switch. See "How 802.1x Authentication Affects VLAN
Operation" in the Access Security Guide for your switch.
During RADIUS-authenticated client sessions, access to a VLAN on the
port used for the client sessions is lost. If the affected VLAN is config-
ured as untagged on the port, it may be temporarily blocked on that port during
an 802.1x session. This is because the switch has temporarily assigned another
VLAN as untagged on the port to support the client access, as specified in the
response from the RADIUS server. See "How 802.1x Authentication Affects
VLAN Operation" in the Access Security Guide for your switch.
The switch appears to be properly configured as a supplicant, but
cannot gain access to the intended authenticator port on the switch
to which it is connected. If
aaa authentication port-access is configured for
Local, ensure that you have entered the local login (operator-level)
username and password of the authenticator switch into the
identity and
secret parameters of the supplicant configuration. If instead, you enter
the enable (manager-level) username and password, access will be
denied. The supplicant statistics listing shows multiple ports with the
same authenticator MAC address. The link to the authenticator may have
been moved from one port to another without the supplicant statistics having
been cleared from the first port. Refer to the "Note on Supplicant Statistics"
in the Access Security Guide for your switch.
The
show port-access authenticator < port-list > command shows one or more
ports remain open after they have been configured with
control
unauthorized
. 802.1x is not active on the switch. After you execute aaa port-
access authenticator active
, all ports configured with control unauthorized should be
listed as
Closed.
!Software.book Page 10 Thursday, October 10, 2002 6:10 PM

Table of Contents

Other manuals for HP ProCurve 2650

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve 2650 and is the answer not in the manual?

HP ProCurve 2650 Specifications

General IconGeneral
Switching Capacity13.6 Gbps
Forwarding Rate10.1 Mpps
Layer2
Jumbo Frame SupportYes
Form FactorRack-mountable
VLAN SupportYes
Layer 3 RoutingNo
PoE SupportNo
FanlessNo
AltitudeUp to 3, 000 meters
ManagementCLI, SNMP
Operating Temperature0°C to 50°C
Storage Temperature-40°C to 70°C
Humidity15% to 95% non-condensing

Related product manuals