8-12
Time Protocols
SNTP: Viewing, Selecting, and Configuring
Figure 8-6. Example of Specifying the SNTP Protocol Version Number
Changing the SNTP Poll Interval. This command lets you specify how
long the switch waits between time polling intervals. The default is 720
seconds and the range is 30 to 720 seconds. (This parameter is separate from
the poll interval parameter used for Timep operation.)
Syntax: sntp poll-interval <30 . . 720>
For example, to change the poll interval to 300 seconds:
HPswitch(config)# sntp poll-interval 300
Disabling Time Synchronization Without Changing the SNTP
Configuration. The recommended method for disabling time synchroniza-
tion is to use the
timesync command. This halts time synchronization without
changing your SNTP configuration.
Syntax: no timesync
For example, suppose SNTP is running as the switch’s time synchronization
protocol, with
Broadcast as the SNTP mode and the factory-default polling
interval. You would halt time synchronization with this command:
HPswitch(config)# no timesync
If you then viewed the SNTP configuration, you would see the following:
Figure 8-7. Example of SNTP with Time Sychronization Disabled
Deletes unicast SNTP server entry.
Re-enters the unicast server with a non-
default protocol version.
show sntp displays the result.
!Software.book Page 12 Thursday, October 10, 2002 6:10 PM

Table of Contents

Other manuals for HP ProCurve 2650

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve 2650 and is the answer not in the manual?

HP ProCurve 2650 Specifications

General IconGeneral
Switching Capacity13.6 Gbps
Forwarding Rate10.1 Mpps
Layer2
Jumbo Frame SupportYes
Form FactorRack-mountable
VLAN SupportYes
Layer 3 RoutingNo
PoE SupportNo
FanlessNo
AltitudeUp to 3, 000 meters
ManagementCLI, SNMP
Operating Temperature0°C to 50°C
Storage Temperature-40°C to 70°C
Humidity15% to 95% non-condensing

Related product manuals