EasyManuals Logo

HP ProCurve 2650 User Manual

HP ProCurve 2650
524 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #157 background imageLoading...
Page #157 background image
8-11
Time Protocols
SNTP: Viewing, Selecting, and Configuring
Note Deleting an SNTP server when only one is configured disables SNTP unicast
operation.
For example, to select SNTP and configure it with unicast mode and an SNTP
server at 10.28.227.141 with the default server version (3) and default poll
interval (720 seconds):
HPswitch(config)# timesync sntpSelects SNTP.
HPswitch(config)# sntp unicastActivates SNTP in Unicast mode.
HPswitch(config)# sntp server 10.28.227.141Specifies the
SNTP server and accepts the
current SNTP server version
(default: 3).
.
Figure 8-5. Example of Configuring SNTP for Unicast Operation
If the SNTP server you specify uses SNTP version 4 or later, use the sntp server
command to specify the correct version number. For example, suppose you
learned that SNTP version 4 was in use on the server you specified above (IP
address 10.28.227.141). You would use the following commands to delete the
server IP address and then re-enter it with the correct version number for that
server:
In this example, the Poll Interval and the Protocol
Version appear at their default settings.
Note: Protocol Version appears only when there is an
IP address configured for an SNTP server.
!Software.book Page 11 Thursday, October 10, 2002 6:10 PM

Table of Contents

Other manuals for HP ProCurve 2650

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve 2650 and is the answer not in the manual?

HP ProCurve 2650 Specifications

General IconGeneral
Switching Capacity13.6 Gbps
Forwarding Rate10.1 Mpps
Layer2
Jumbo Frame SupportYes
Form FactorRack-mountable
VLAN SupportYes
Layer 3 RoutingNo
PoE SupportNo
FanlessNo
AltitudeUp to 3, 000 meters
ManagementCLI, SNMP
Operating Temperature0°C to 50°C
Storage Temperature-40°C to 70°C
Humidity15% to 95% non-condensing

Related product manuals