8-18
Time Protocols
TimeP: Viewing, Selecting, and Configuring
For example, suppose:
Time synchronization is configured for SNTP.
You want to:
1. View the current time synchronization.
2. Select TimeP as the time synchronization mode.
3. Enable TimeP for DHCP mode.
4. View the TimeP configuration.
The commands and output would appear as follows:
Figure 8-12. Example of Enabling TimeP Operation in DHCP Mode
Enabling Timep in Manual Mode. Like DHCP mode, configuring TimeP for
Manual mode enables TimeP. However, for manual operation, you must also
specify the IP address of the TimeP server. (The switch allows only one TimeP
server.) To enable the TimeP protocol:
Syntax: timesync timep Selects Timep.
ip timep manual <ip-addr> Activates TimeP in Manual mode with a
specified TimeP server.
no ip timep Disables TimeP.
Note
To change from one TimeP server to another, you must (1) use the no ip timep
command to disable TimeP mode, and then reconfigure TimeP in Manual
mode with the new server IP address.
show timep displays the TimeP configuration and also shows
that SNTP is the currently active time synchronization mode.
show timep again displays the TimeP configuration and shows
that TimeP is now the currently active time synchronization mode.
!Software.book Page 18 Thursday, October 10, 2002 6:10 PM

Table of Contents

Other manuals for HP ProCurve 2650

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve 2650 and is the answer not in the manual?

HP ProCurve 2650 Specifications

General IconGeneral
Switching Capacity13.6 Gbps
Forwarding Rate10.1 Mpps
Layer2
Jumbo Frame SupportYes
Form FactorRack-mountable
VLAN SupportYes
Layer 3 RoutingNo
PoE SupportNo
FanlessNo
AltitudeUp to 3, 000 meters
ManagementCLI, SNMP
Operating Temperature0°C to 50°C
Storage Temperature-40°C to 70°C
Humidity15% to 95% non-condensing

Related product manuals