8-20
Time Protocols
TimeP: Viewing, Selecting, and Configuring
If you then viewed the TimeP configuration, you would see the following:
Figure 8-14. Example of TimeP with Time Sychronization Disabled
Disabling the TimeP Mode. Disabling the TimeP mode means to configure
it as disabled. (Disabling TimeP prevents the switch from using it as the time
synchronization protocol, even if it is the selected
Time Sync Method option.)
Syntax: no ip timep Disables TimeP by changing the TimeP mode
configuration to
Disabled.
For example, if the switch is running TimeP in DHCP mode,
no ip timep changes
the TimeP configuration as shown below, and disables time synchronization
on the switch.
Figure 8-15. Example of Disabling Time Synchronization by Disabling the TimedP
Mode Parameter
Even though the Time Sync Mode is set to Timep,
time synchronization is disabled because no ip
timep has disabled the TimeP Mode parameter.
!Software.book Page 20 Thursday, October 10, 2002 6:10 PM

Table of Contents

Other manuals for HP ProCurve 2650

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve 2650 and is the answer not in the manual?

HP ProCurve 2650 Specifications

General IconGeneral
Switching Capacity13.6 Gbps
Forwarding Rate10.1 Mpps
Layer2
Jumbo Frame SupportYes
Form FactorRack-mountable
VLAN SupportYes
Layer 3 RoutingNo
PoE SupportNo
FanlessNo
AltitudeUp to 3, 000 meters
ManagementCLI, SNMP
Operating Temperature0°C to 50°C
Storage Temperature-40°C to 70°C
Humidity15% to 95% non-condensing

Related product manuals