9-19
Optimizing Traffic Flow with Port Controls, Port Trunking, and Port-Based Priority
Port Trunking
Using a port list specifies, for switch ports in a static trunk group, only the
ports you want to view. In this case, the command specifies ports A5 through
A7. However, because port A6 is not in a static trunk group, it does not appear
in the resulting listing:
Figure 9-8. Example Listing Specific Ports Belonging to Static Trunks
The show trunks [ e ] < port-list > command in the above example includes a
port list, and thus shows trunk group information only for specific ports that
have membership in a static trunk. In figure 9-9-9, the command does not
include a port list, so the switch lists all ports having static trunk membership.
Figure 9-9. Example of a Show Trunk Listing Without Specifying Ports
Port A5 appears with an example of a name that you can optionally assign using the
Friendly Port Names feature. (See “Using Friendly (Optional) Port Names” on page 6-15.)
Port A6 does not appear in this listing because
it is not assigned to a static trunk.
!Software.book Page 19 Thursday, October 10, 2002 6:10 PM

Table of Contents

Other manuals for HP ProCurve 2650

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProCurve 2650 and is the answer not in the manual?

HP ProCurve 2650 Specifications

General IconGeneral
Switching Capacity13.6 Gbps
Forwarding Rate10.1 Mpps
Layer2
Jumbo Frame SupportYes
Form FactorRack-mountable
VLAN SupportYes
Layer 3 RoutingNo
PoE SupportNo
FanlessNo
AltitudeUp to 3, 000 meters
ManagementCLI, SNMP
Operating Temperature0°C to 50°C
Storage Temperature-40°C to 70°C
Humidity15% to 95% non-condensing

Related product manuals